Contents
  1. Thermaroof TR26 LPC/FM | Insulation | Kingspan | MEA & India
  2. Insulation Products and Systems
  3. Kingspan Thermaroof TR26 2400mm x 1200mm x 140mm
  4. Vast Insulation Range Available

These examples are based on Kingspan Thermaroof® TR LPC/FM, waterproofed using a mechanically fixed single–ply membrane. The insulation board is. SPECIFICATION CLAUSE. Kingspan Thermaroof TR26 LPC/FM zero ODP should be described in specifications as:–. The roof insulation shall be Kingspan . Waterproofing e.g. single–ply non–bituminous membrane. mm concrete deck. Telescopic tube fastener. Kingspan Thermaroof®. TR26 LPC/FM (mm).

Author:MARISSA BERGDOLL
Language:English, Spanish, Arabic
Country:Kuwait
Genre:Academic & Education
Pages:570
Published (Last):10.11.2015
ISBN:171-8-46612-858-6
Distribution:Free* [*Register to download]
Uploaded by: ROCCO

65070 downloads 147589 Views 15.55MB PDF Size Report


Kingspan Tr26 Pdf

Kingspan Thermaroof TR26 LPC/FM is a, FM approved high performance foil faced PIR insulation for flat roofing applications. (Thermaroof TR26 LPC/FM & Thermaroof TR27 LPC/FM). Partially Bonded Built Up Felt and Mastic Asphalt Waterproofing. • Kingspan Thermaroof® TR available in pdf format via the UKAS link on the BBA website at TR26 LPC/FM and Thermataper TT46 LPC/FM Roofing Boards.

The void created by a pitched roof can be made habitable by insulating along the plane of the roof pitch with Celotex rigid PIR insulation boards. This creates a warm, potentially habitable, roof space in which water pipes and tanks no longer need to be insulated. Where headroom and rafter depth is limited, Celotex insulation may be fitted between and over the rafters. If this two-layer solution is chosen, it is important that the thermal resistance of the inner layer between the rafters , is less than that of the outer layer over the rafters. This reduces the risk of interstitial condensation between the insulation layers. The condensation risk also depends upon occupancy and building use. Celotex therefore recommends that a condensation risk analysis is obtained to determine the optimum solution for individual projects. Please contact the Celotex Technical Advisory Service for further information. GA Range To buy click here Celotex GA range boards This creates a warm, potentially habitable roof space in which water pipes and tanks no longer need to be insulated. If BS slater's felt is being used, a minimum 50 mm ventilated air space must be provided between the felt and the cold side of the insulation in order to minimise the risk of condensation formation. This construction is known as a ventilated construction. With some breathable membranes, the cold side of the insulation may be placed in direct contact with the membrane check with membrane supplier prior to specification.

Warmfast vapour barrier should also be used.

Thermaroof TR26 LPC/FM | Insulation | Kingspan | MEA & India

Bonded insulations Metdeck is a high quality Kingspan rigid board bonded to 18mm exterior grade plywood. Metdeck offers high insulation value with minimal construction height.

All edges of both the OSB and the Insulation itself are channelled preventing the uncontrolled vapour drive that occurs with butt jointed insulation boards. The technical team at Linzmeir are on hand to assist with all technical aspects from start to finish ensuring that the whole system works in harmony.

Warmfast Vapour Barrier should also be used.

Insulation Products and Systems

Puren M is a combination of rigid board with timber lathes bonded at centres. Puren provide the whole system including vapour barrier.

As with Linitherm,the technical team at Mifaro, Worldwide suppliers of Puren M to the distributor market are on hand to assist with all technical aspects from start to finish ensuring that the whole system works in harmony. Foamglas is a closed cell insulation impervious to vapour and highly fire resistant.

This is known as an unventilated construction. This creates a warm, potentially habitable roof space in which water pipes and tanks no longer need to be insulated.

Kingspan Thermaroof TR26 2400mm x 1200mm x 140mm

If sarking felt is being used, a minimum 50 mm ventilated air space must be provided between the felt and the cold side of the insulation in order to minimise the risk of condensation formation. This is known as ventilated construction.

One of the most common alterations made to older houses with pitched roofing is to convert the loft space into a habitable living space. This can add value to an existing property and, in many cases, allows families to grow without having to move from a favoured property. The creation of a habitable space also requires the incorporation of adequate thermal insulation to meet the requirements of the building regulations.

The major benefit of using Celotex PIR insulation boards is that the efficiency of the product allows the occupants to lose the minimum of internal space - thereby maximising the internal space. Insulating a loft area will frequently require many different insulation solutions involving walls, as well as pitched and flat roof areas.

When designing a flat roof using Celotex Tempchek TA3 boards, three basic principles apply: Design to a fall of , or as appropriate to the weathering system, type of deck and construction tolerances. Have due regard for the use and design of the building and the need to ensure that the design will not allow a build up of moisture below the waterproofing membrane.

Vast Insulation Range Available

Provide adequate protection for both insulation and waterproofing if significant foot traffic is expected either during or after completion of the roof. Discounts calculated automatically.